mHealth App for Pressure Ulcer Wound Assessment in Patients With Spinal Cord Injury: Clinical Validation Study

Archive ouverte : Article de revue

Do Khac, Ariane | Jourdan, Claire | Fazilleau, Sylvain | Palayer, Claire | Laffont, Isabelle | Dupeyron, Arnaud | Verdun, Stéphane | Gelis, Anthony

Edité par HAL CCSD ; JMIR Publications

International audience. Clinical evaluation of a pressure ulcer is based on quantitative and qualitative evaluation. In clinical practice, acetate tracing is the standard technique used to measure wound surface area; however, it is difficult to use in daily practice (because of material availability, data storage issues, and time needed to calculate the surface area). Planimetry techniques developed with mobile health (mHealth) apps can be used to overcome these difficulties. Objective The goal of this study was to evaluate the metrological properties of a free-access mHealth app, called imitoMeasure, to assess pressure ulcers.Methods This was a noninterventional, validation study. We included patients with spinal cord injury presenting with a pressure ulcer, regardless of its stage or location. We performed wound measurements with a ruler, and we performed acetate tracing using a transparent dressing with a wound measurement grid. Wound evaluation via the mHealth app was conducted twice by the main investigator and also by a coinvestigator to determine validity, intrarater reproducibility, and interrater reproducibility. Bland-Altman plots and intraclass correlation coefficients were used to compute the minimal detectable change percentage.Results Overall, 61 different pressure ulcers were included. The validity, intrarater reproducibility, and interrater reproducibility of the mHealth app vs acetate tracing (considered the method of reference) were good, with intraclass correlation coefficients of 0.97 (95% CI 0.93-0.99), 0.99 (95% CI 0.98-0.99), and 0.98 (95% CI 0.96-0.99), respectively, and minimal detectable change percentages between 17% and 35%.Conclusions The imitoMeasure app had good validity and reproducibility. It could be an alternative to standard wound assessment methods. Further studies on larger and more diverse wounds are needed.

Consulter en ligne

Suggestions

Du même auteur

La plasticité cérébrale / coordonné par J. Froger, I. Laffont, A. Dupeyron....

Livre | Froger, Jérôme (19..-....) - médecin. Directeur de publication | 2017

Toxine botulique et appareil locomoteur : [46e Entretiens de Médecine Physi...

Livre | Coroian, Flavia Oana (1972-....). Directeur de publication | 2018

Long-term outcomes of primary cystocele repair by transvaginal mesh surgery...

Archive ouverte: Article de revue

Lucot, Jean Philippe | 2022

International audience. Objective: To compare the effectiveness and safety of laparoscopic sacropexy (LS) and transvaginal mesh (TVM) at 4 years. Design: Extended follow up of a randomised trial. Setting: Eleven cen...

Du même sujet

Variability in the analysis of a single neuroimaging dataset by many teams

Archive ouverte: Article de revue

Botvinik-Nezer, Rotem | 2020-06-04

International audience. Data analysis workflows in many scientific domains have become increasingly complex and flexible. Here we assess the effect of this flexibility on the results of functional magnetic resonance...

Human low-threshold mechanoafferent responses to pure changes in friction c...

Archive ouverte: Article de revue

Dione, Mariama | 2021

International audience. Abstract The forces that are developed when manipulating objects generate sensory cues that inform the central nervous system about the qualities of the object’s surface and the status of the...

Biais de positivité : lorsque la conscience du temps qui passe nous fait po...

Archive ouverte: Communication dans un congrès

Degraeve, Béatrice | 2022-03-19

BOLD fMRI to assess the impact of alcohol advertisements in young drinkers

Archive ouverte: Communication dans un congrès

Duché, Quentin | 2020-06-23

International audience

MSCopilot: New smartphone-based digital biomarkers correlate with Expanded ...

Archive ouverte: Article de revue

Tanoh, Ian-Christopher | 2021-10

International audience. Background: A previous clinical study showed the high specificity, sensitivity and reliability of MSCopilot, a software medical device designed by Ad Scientiam for the self-assessment of peop...

The tactile perception of transient changes in friction

Archive ouverte: Article de revue

Gueorguiev, David | 2017-12-06

International audience

Chargement des enrichissements...