Assessment of left ventricular size and function by 3-dimensional transthoracic echocardiography: Impact of the echocardiography platform and analysis software

Archive ouverte : Article de revue

Castel, Anne Laure | Toledano, Manuel | Tribouilloy, Christophe | Delelis, Francois | Mailliet, Amandine | Marotte, Nathalie | Guerbaai, Raphaëlle-Ashley | Levy, Franck | Graux, Pierre | Ennezat, Pierre-Vladimir | Marechaux, Sylvestre

Edité par HAL CCSD ; Elsevier

International audience. Background: Whether echocardiography platform and analysis software impact left ventricular (LV) volumes, ejection fraction (EF), and stroke volume (SV) by transthoracic tridimensional echocardiography (3DE) has not yet been assessed. Hence, our aim was to compare 3DE LV end-diastolic and end-systolic volumes (EDV and ESV), LVEF, and SV obtained with echocardiography platform from 2 different manufacturers. Methods: 3DE was performed in 84 patients (65% of screened consecutive patients), with equipment from 2 different manufacturers, with subsequent off-line postprocessing to obtain parameters of LV function and size (Philips QLAB 3DQ and General Electric EchoPAC 4D autoLVQ). Twenty-five patients with clinical indication for cardiac magnetic resonance imaging served as a validation subgroup. Results: LVEDV and LVESV from 2 vendors were highly correlated (r=0.93), but compared with 4D autoLVQ, the use of Qlab 3DQ resulted in lower LVEDV and LVESV (bias: 11 mL, limits of agreement: -25 to + 47 and bias: 6 mL, limits of agreement: -22 to + 34, respectively). The agreement between LVEF values of each software was poor (intraclass correlation coefficient 0.62) despite no or minimal bias. SVs were also lower with Qlab 3DQ advanced compared with 4D autoLVQ, and both were poorly correlated (r=0.66). Consistently, the underestimation of LVEDV, LVESV, and SV by 3DE compared with cardiac magnetic resonance imaging was more pronounced with Philips QLAB 3DQ advanced than with 4D autoLVQ. Conclusions: The echocardiography platform and analysis software significantly affect the values of LV parameters obtained by 3DE. Intervendor standardization and improvements in 3DE modalities are needed to broaden the use of LV parameters obtained by 3DE in clinical practice. (C) 2018 Elsevier Inc. All rights reserved.

Consulter en ligne

Suggestions

Du même auteur

Relationship Between the Ratio of Acceleration Time/Ejection Time and Morta...

Archive ouverte: Article de revue

Altes, Alexandre | 2021

International audience. Background The ratio of acceleration time/ejection time (AT/ET) is a simple and reproducible echocardiographic parameter that integrates aortic stenosis severity and its consequences on the l...

Quantitative assessment of primary mitral regurgitation using left ventricu...

Archive ouverte: Article de revue

Levy, Franck | 2018

International audience. Background. - Quantitative assessment of primary mitral regurgitation (MR) using left ventricular (LV) volumes obtained with three-dimensional transthoracic echocardiography (3D TTE) recently...

Global longitudinal strain software upgrade: Implications for intervendor c...

Archive ouverte: Article de revue

Castel, Anne-Laure | 2016

International audience. Background. Speckle tracking can be used to measure left ventricular global longitudinal strain (GLS). Aims. To study the effect of speckle tracking software product upgrades on GLS values an...

Du même sujet

Proteolytic activity of Lactobacillus strains isolated from Mongolian tradi...

Archive ouverte: Article de revue

Raveschot, Cyril | 2020-01-30

Le Réseau Mixte Technologique Sols et Territoires : développer la connaissa...

Archive ouverte: Article de revue

Guellier, Camille | 2014

absent

Soil bioindicators: how soil properties influence their responses and to se...

Archive ouverte: Communication dans un congrès

Pauget, Benjamin | 2015-05-03

International audience

Les incitations financières à la réalisation d’objectifs comportementaux li...

Archive ouverte: Article de revue

Crainich, David | 2022-02

International audience. Les programmes octroyant des récompenses pécuniaires aux individus qui parviennent à atteindre un objectif lié à la santé (arrêter de fumer, perdre du poids, etc.) ont pour but de favoriser l...

Transcriptome assembly and abiotic related gene expression analysis of date...

Archive ouverte: Article de revue

Rekik, Imen | 2019-11-30

Characterization of free exopolysaccharides secreted by Mycoplasma myco...

Archive ouverte: Article de revue

Bertin, Clothilde | 2013

International audience. Contagious bovine pleuropneumonia is a severe respiratory disease of cattle that is caused by a bacterium of the Mycoplasma genus, namely Mycoplasma mycoides subsp. mycoides (Mmm). In the abs...

Chargement des enrichissements...