Wearable cardioverter-defibrillator in patients with a transient risk of sudden cardiac death: the WEARIT-France cohort study

Archive ouverte : Article de revue

Garcia, Rodrigue | Combes, Nicolas | Defaye, Pascal | Narayanan, Kumar | Guedon-Moreau, Laurence | Boveda, Serge | Blangy, Hugues | Bouet, Jérôme | Briand, Florent | Chevalier, Philippe | Cottin, Yves | da Costa, Antoine | Degand, Bruno | Deharo, Jean-Claude | Eschalier, Romain | Extramiana, Fabrice | Goralski, Marc | Guy-Moyat, Benoit | Guyomar, Yves | Hermida, Jean-Sylvain | Jourda, François | Lellouche, Nicolas | Mahfoud, Mohanad | Manenti, Vladimir | Mansourati, Jacques | Martin, Angéline | Pasquié, Jean-Luc | Ritter, Philippe | Rollin, Anne | Tibi, Thierry | Yalioua, Arab | Gras, Daniel | Sadoul, Nicolas | Piot, Olivier | Leclercq, Christophe | Marijon, Eloi

Edité par HAL CCSD ; Oxford University Press (OUP)

International audience. Abstract Aims We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. Methods and results Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37–97) days. Median daily wear time of WCD was 23.4 (22.2–23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95–0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). Conclusion Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.

Consulter en ligne

Suggestions

Du même auteur

Prediction of Systemic Septic Embolism in Patients With Left-Sided Infectiv...

Archive ouverte: Article de revue

Bernard, Anne | 2017-04

International audience

Predicting Clinical and Echocardiographic Response After Cardiac Resynchron...

Archive ouverte: Article de revue

Bernard, Anne | 2017-06

International audience. The L2ANDS2 score was previously found to be able to assess the probability of left ventricular (LV) remodeling. We sought to evaluate this score in terms of clinical outcomes: 275 patients w...

Clinical significance of septal deformation patterns in heart failure patie...

Archive ouverte: Article de revue

Menet, Aymeric | 2017-12-01

International audience. Aims Specific septal motion related to dyssynchrony is strongly linked to reverse remodelling, in patients with systolic heart failure (HF) receiving cardiac resynchronization therapy (CRT). ...

Du même sujet

Gynécologie, obstétrique / sous l'égide du Collège national des gynécologue...

Livre | Deruelle, Philippe (1971-....). Directeur de publication | 2021 - 5e édition

L'ouvrage En parfaite conformité avec le programme de DFASM (diplôme de formation approfondie en sciences médicales) s'inscrivant dans la réforme du 2e cycle 2021 (R2C 2021) cet ouvrage rassemble l'ensemble des connaissances indis...

Abrégé d'anatomie et de physiologie humaines : les fondamentaux / Michel La...

Livre | Lacombe, Michel (1929-2011) - chirurgien. Auteur | 2006 - 6e édition

Penser le futur : un enjeu d'éducation pour faire face à l'anthropocène / N...

Livre | Hervé, Nicolas (1978-....) - enseignant-chercheur en didactique des technosciences. Auteur | 2022

L’Anthropocène questionne les modes de vie à plus d’un titre. Notre société va-t-elle s’effondrer ? L’avenir de la Terre est-il sur Mars ? Le futur est-il nécessairement décroissant ? Faut-il développer les voitures électriques et...

Dermatologie / sous l'égide du Collège des enseignants en dermatologie de F...

Livre | Gaudy-Marqueste, Caroline (1975-....). Directeur de publication | 2022 - 8e édition

En parfaite cohérence avec le programme de DFASM et les EDN, et en conformité avec la R2C 2021, cet ouvrage rassemble les connaissances fondamentales en dermatologie. Il présente dans le détail les 24 items du programme relevant d...

Je réussis mon semestre 1, IFSI / Pascal Hallouët,... Gwenhaéla Dagorne,......

Livre | Hallouët, Pascal (19..-....) - formateur en soins infirmiers. Auteur | 2019

Plus de 60 fiches de révision organisées selon la chronologie des études proposent : - les notions et concepts spécifiques à retenir ;- le rôle de l'IDE et des conseils pratiques ; - des cas cliniques favorisant l'intégration des ...

Mini manuel biochimie : cours + exos + QCM-QROC / Paul-François Gallet,... ...

Livre | Gallet, Paul-François (1965-....). Auteur | 2020 - 4e édition

"Comment aller à l'essentiel, comprendre les méthodes et les démarches avant de les mettre en application ? Conçus pour faciliter l'apprentissage des notions essentielles, les Mini Manuels proposent : . un cours concis et richemen...

Chargement des enrichissements...