Electrochemical and electronic detection of biomarkers in serum: a systematic comparison using aptamer-functionalized surfaces

Archive ouverte : Article de revue

Mishyn, Vladyslav | Rodrigues, Teresa | Leroux, Yann R. | Butruille, Laura | Woitrain, Eloise | Montaigne, David | Aspermair, Patrik | Happy, Henri | Knoll, Wolfgang | Boukherroub, Rabah | Szunerits, Sabine

Edité par HAL CCSD ; Springer Verlag

International audience. Sensitive and selective detection of biomarkers in serum in a short time has a significant impact on health. The enormous clinical importance of developing reliable methods and devices for testing serum levels of cardiac troponin I (cTnI), which are directly correlated to acute myocardial infarction (AMI), has spurred an unmatched race among researchers for the development of highly sensitive and cost-effective sensing formats to be able to differentiate patients with early onset of cardiac injury from healthy individuals with a mean cTnI level of 26 pg mL-1. Electronic- and electrochemical-based detection schemes allow for fast and quantitative detection not otherwise possible at the point of care. Such approaches rely largely on voltammetric and field-effect-based readouts. Here, we systematically investigate electric and electrochemical point-of-care sensors for the detection of cTnI in serum samples by using the same surface receptors, cTnI aptamer-functionalized CVD graphene-coated interdigated gold electrodes. The analytical performances of both sensors are comparable with a limit of detection (LoD) of 5.7 ± 0.6 pg mL-1(electrochemical) and 3.3 ± 1.2 pg mL-1 (electric). However, both sensors exhibit different equilibrium dissociation constant (KD) values between the aptamer-linked surface receptor and the cTnI analyte, being 160 pg mL-1 for the electrochemical and about three times lower for the electrical approach with KD = 51.4 pg mL-1. This difference is believed to be related to the use of a redox mediator in the electrochemical sensor for readout. The ability of the redox mediator to diffuse from the solution to the surface via the cTnI/aptamer interface is hindered, correlating to higher KD values. In contrast, the electric readout has the advantage of being label-free with a sensing limitation due to ionic strength effects, which can be limited using poly(ethylene) glycol surface ligands.

Consulter en ligne

Suggestions

Du même auteur

Highly performing graphene-based field effect transistor for the differenti...

Archive ouverte: Article de revue

Rodrigues, Teresa | 2022-04

International audience. Cardiovascular diseases result in millions of deaths around the globe, many of which could have been avoided if identified at an early stage. Preventive cardiovascular disease diagnostics pla...

Controlled covalent functionalization of a graphene-channel of a field effe...

Archive ouverte: Article de revue

Mishyn, Vladyslav | 2021-09-27

International audience. The controlled covalent functionalization of the graphene channel of a field effect transistor, based on interdigitated gold electrodes (source and drain), via electrochemical grafting, using...

The holy grail of pyrene-based surface ligands on the sensitivity of graphe...

Archive ouverte: Article de revue

Mishyn, Vladyslav | 2022-03-01

International audience. Graphene has received intensive research interest due to its remarkable charge mobility, and the efforts in the use of graphene-based field effect transistors (GFETs) for the sensing of biolo...

Du même sujet

Highly performing graphene-based field effect transistor for the differenti...

Archive ouverte: Article de revue

Rodrigues, Teresa | 2022-04

International audience. Cardiovascular diseases result in millions of deaths around the globe, many of which could have been avoided if identified at an early stage. Preventive cardiovascular disease diagnostics pla...

On the detection of cTnI - a comparison of surface-plasmon optical-electroc...

Archive ouverte: Article de revue

Rodrigues, T. | 2021-03-06

International audience

A CMOS Compatible Thermoelectric Device made of Crystalline Silicon Membran...

Archive ouverte: Article de revue

Bah, Thierno-Moussa | 2022-12-10

International audience. Herein, we report the use of nanostructured crystalline silicon as a thermoelectric material and its integration into thermoelectric devices. The proof-of-concept relies on the partial suppre...

Effet de l'angle de charge sur les harmoniques d'efforts magnétiques dans l...

Archive ouverte: Communication dans un congrès

Le Besnerais, Jean | 2016-06-07

International audience. Cet article étudie l'effet de l'angle de charge sur les efforts harmoniques de Maxwell (tangentiels et radiaux) et les bruits et vibrations d'origine magnétique dans deux machines synchrones ...

Further investigation of convolutional neural networks applied in computati...

Archive ouverte: Article de revue

Gong, Ruohan | 2022-04-07

International audience. Convolutional neural networks (CNN) have shown great potentials and have been proven to be an effective tool for some image-based deep learning tasks in the field of computational electromagn...

Thermal and hygroscopic study of hemp concrete in real ambient conditions

Archive ouverte: Article de revue

Asli, M. | 2021-04

International audience

Chargement des enrichissements...