Actuator Fault and Disturbance Estimation using the T-S fuzzy model

Archive ouverte : Communication dans un congrès

Li, Shanzhi | Wang, Haoping | Aitouche, Abdel | Tian, Yang | Christov, Nicolai

Edité par HAL CCSD

International audience. This paper presents an actuator fault and disturbance estimation strategy using Takagi-Sugeno (TS) fuzzy model. In this approach, using a coordinate transformation, the TS fuzzy system is decomposed into three different modules: state subsystem without fault and disturbance, disturbance subsystem without fault, fault subsystem without disturbance. After the transformation, the fault and disturbance can be decoupled and calculated from the input and output signals and estimation state. The convergence of TS fuzzy observer is analyzed and proved. In order to verify the performance of the proposed approach, a wind turbine system with actuator fault and disturbance have been tested, the simulation results illustrate the efficiency of the proposed strategy.

Consulter en ligne

Suggestions

Du même auteur

Active Fault Tolerant Control system Using Unknown Input Observer with Actu...

Archive ouverte: Article de revue

Li, Shanzhi | 2018-03-25

International audience

Sensor fault estimation of PEM fuel cells using Takagi Sugeno fuzzy model

Archive ouverte: Article de revue

Li, Shanzhi | 2019

International audience

Sensor Fault Estimation of a PEM Fuel Cell using Takagi Sugeno Fuzzy Model

Archive ouverte: Communication dans un congrès

Li, Shanzhi | 2017-11-16

International audience

Du même sujet

Sliding mode observer design for fault and disturbance estimation using Tak...

Archive ouverte: Article de revue

Li, Shanzhi | 2018

International audience. This paper presents an actuator fault and disturbance estimation scheme using sliding mode observer(SMO)basedonTakagi-Sugeno(TS)fuzzy system model. The TS model is first transformed in order ...

Active fault tolerant control of wind turbine systems based on DFIG with ac...

Archive ouverte: Article de revue

Li, Shanzhi | 2018

International audience. This paper presents an active fault tolerant control (FTC) for doubly fed induction generator (DFIG) with actuator fault and disturbance using Takagi-Sugeno(TS) fuzzy model. The control struc...