An On-line Method for Stator Fault Detection in Multi-phase PMSM Drives

Archive ouverte : Communication dans un congrès

Meinguet, Fabien | Semail, Eric | Gyselinck, Johan

Edité par HAL CCSD ; IEEE - Institute of Electrical and Electronics Engineers

International audience. This paper deals with an on-line fault detection method for multi-phase PMSM drives. The method is based on the detection of the stator current positive- and negative sequence fundamental components expressed in the stationary αβ reference frame. These components allow calculating a fault index used for the detection of stator faults, such as open-circuit faults. The decision criterion is based on the CUSUM algorithm. A model of a five-phase machine with one single-phase open-circuit is derived and validated with experimental results. Then, it is shown that the proposed method achieves fault detection on a wide speed range and even during speed transient.

Consulter en ligne

Suggestions

Du même auteur

Enhanced Torque Control of a PMSM Supplied by a Four-Leg Voltage Source Inv...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2008-09-06

This paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg is clamped...

A change-detection algorithm for short-circuit fault detection in closed-lo...

Archive ouverte: Article de revue

Meinguet, Fabien | 2014

The authors would like to thank the Belgian F.R.I.A. for the funding of this research project. International audience. This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-vo...

Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM ...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2011-06-28

International audience. This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered f...

Du même sujet

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with ...

Archive ouverte: Article de revue

Nguyen, Ngac Ky | 2015-01

International audience. Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuitfault, it is...

Real-Time Switches Fault Diagnosis Based on Typical Operating Characteristi...

Archive ouverte: Article de revue

Trabelsi, Mohamed | 2016

International audience. A novel centroid-based diagnostic method of the power switches in five-leg Voltage Source Inverter (VSI) is proposed in this paper. Using a vectorial multi-machine description, a five-phase d...

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with ...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2013-12-10

The authors would like to thank the ADEME for the funding of the MHYGALE project.. Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inve...

Inductances and back-emf harmonics influence on the Torque/Speed characteri...

Archive ouverte: Communication dans un congrès

Scuiller, Franck | 2014-10

In this paper, the study of torque/speed characteristic for five-phase Surface-mounted Permanent Magnet (SPM) machine is carried out. With considering several hypothesis (linear magnetic modelling, only first and third harmonic te...

Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM ...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2011-06-28

International audience. This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered f...

Different Virtual Stator Winding Configurations of Open-End Winding Five-Ph...

Archive ouverte: Communication dans un congrès

Nguyen, N.K | 2013-09-03

International audience. This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pe...

Chargement des enrichissements...