conception of high functional reality multi-machines multi-converter drive s. Conception d'entrainement multimachines multi-convertisseurs à haut niveau de fiabilité fonctionnelle

Archive ouverte : Thèse

dos Santos Moraes, Tiago José

Edité par HAL CCSD

In airplanes and launch vehicles, hydraulics, mechanical and pneumatic systems are progressively being replaced by electric systems for technical and industrial reasons. However, these new electric systems have to take into account the economical and weight reliability constraints of the aeronautics industry, ensuring the required reliability. Therefore, novel high reliability multi-machine and multi-converter topologies are compared to standard structures looking forward to find solutions that can be industrially implemented. Then, series-coupled machine topologies were chosen for this work. The series-coupling mutualizes the inverter legs, reducing their number, and increases the total electrical resistance of the system. As a consequence, the peak-current after the occurrence of certain faults is reduced, but the total copper losses are higher. In order to independently control the series-coupled machines, it is highlighted the reason why the number of phases must be higher than 3 and with a special electric coupling that permutes the machine’s phases. A new patented topology is deeply analyzed with experimental tests. After a validation of the studied system, more complex control strategies and control reconfiguration after a fault are also implemented in order to evaluate the potential improvements on the system performance in degraded mode. Simulation and experimental results were used on this study. For this analysis the dimensioning power of the inverter, the copper losses and the torque ripple, all of them in degraded mode, are the compared criterions. . Dans les avions et lanceurs, des systèmes entraînés par l’énergie hydraulique, mécanique ou pneumatique sont progressivement remplacés par des systèmes électriques pour des raisons techniques et industrielles. Cependant, ces nouveaux systèmes doivent répondre aux contraintes économiques et de poids concernant ces domaines tout en garantissant une certaine fiabilité. Dans ce contexte industriel, des topologies innovantes multi-machines multi-convertisseurs à haut niveau de fiabilité sont comparées ici à des structures plus standards toujours tolérantes aux défaillances. Ainsi, des topologies avec des machines polyphasées couplées électriquement en série ont été choisies pour ce travail de thèse. La mise en série permet la mutualisation des bras d’onduleurs, réduisant ainsi leur nombre, et augmente la résistance totale du système. La valeur crête du courant est alors réduite lors de l’apparition de certains défauts avec, comme contrepartie, une augmentation inéluctables des pertes Joule globales. Pour que le contrôle de ces machines couplées électriquement en série soit indépendant, il est mis en évidence pourquoi le nombre de phase de ces machines doit être supérieur à 3 et avec de plus une connexion électrique spéciale permutant les phases. Une nouvelle topologie brevetée est tout particulièrement étudiée et testée expérimentalement. Apres validation du concept, des stratégies de contrôle plus complexes et des reconfigurations de la commande après le défaut sont appliquées afin de juger des potentialités d’amélioration des systèmes Pour les comparaisons, des simulations et des essais expérimentaux ont été réalisés. Les critères choisis pour cette comparaison ont été la puissance de dimensionnement de l’onduleur, servant d’image de son coût et de son poids, les pertes Joule et le couple pulsatoire, tous les trois pour un fonctionnement en mode dégradé.

Consulter en ligne

Suggestions

Du même auteur

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2015-06

International audience. This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in...

Generalized Vectorial Formalism – based multiphase series-connected motors ...

Archive ouverte: Communication dans un congrès

Semail, Eric | 2015-10

Multiphase drives are more and more used in specific applications leading to a necessity of control strategy development. This paper presents the Generalized Vectorial Formalism (GVF) theory to control multiphase series-connected ...

Fault Tolerant Dual-Motor Drives: Sizing of Power Electronic

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2015-09

International audience. This paper analyzes two dual-motor fault-tolerant topologies. The first one supplies independently both machines while the second one connects them in series for reducing the number of transi...

Du même sujet

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with ...

Archive ouverte: Article de revue

Nguyen, Ngac Ky | 2015-01

International audience. Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuitfault, it is...

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with ...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2013-12-10

The authors would like to thank the ADEME for the funding of the MHYGALE project.. Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inve...

Vectorial Modeling and Control of Multiphase Machines with Non-salient Pole...

Archive ouverte: Type de document indéfini

Kestelyn, Xavier | 2012

International audience. This chapter is devoted to the modeling and control of electrical machines having at least two independent statoric currents. The star-coupled three-phase machine without a neutral terminal o...

Les facteurs humains dans la gestion des risques : évolution de la pensée e...

Livre | Bieder, Corinne. Auteur | 2006

"Une erreur humaine serait à l'origine de l'accident...". L'analyse des accidents révèle souvent des divergences de vues sur le rôle des facteurs humains dans la sécurité. Les facteurs humains dans la gestion des risques pro...

Inductances and back-emf harmonics influence on the Torque/Speed characteri...

Archive ouverte: Communication dans un congrès

Scuiller, Franck | 2014-10

In this paper, the study of torque/speed characteristic for five-phase Surface-mounted Permanent Magnet (SPM) machine is carried out. With considering several hypothesis (linear magnetic modelling, only first and third harmonic te...

Different Virtual Stator Winding Configurations of Open-End Winding Five-Ph...

Archive ouverte: Communication dans un congrès

Nguyen, N.K | 2013-09-03

International audience. This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pe...

Chargement des enrichissements...