Comparison of five-phase, six-phase and seven-phase fault tolerant electric drives

Archive ouverte : Communication dans un congrès

Ribiere, Antonin | Nguyen, Ngac-Ky | Semail, Eric | Espanet, Christophe

Edité par HAL CCSD ; IEEE

International audience. Automotive industry is evolving towards more fault-tolerant actuators to fulfill future autonomous vehicles requirements. Critical applications such as steering or braking have to resist to fault occurrences while being low cost due to mass production market. Considering these two criteria, multiphase electric drives offer a good tradeoff between increasing the degrees of freedom and limiting system oversizing. This paper proposes to compare three multiphase electric drives for electro-hydraulic power steering for trucks: a five-phase machine and a six-phase machine both fed by a full bridge inverter (FBI), and a seven-phase machine fed by a standard half-bridge inverter (HBI). Several comparison criteria are considered in the meantime: motor, electronics, control and manufacturing parameters. Some of criteria are obtained from finite-element analysis (FEA), while others are derived from analytic formula or dynamic simulations . Criteria are evaluated for each drive and then results are discussed. In the given low-voltage high-current application, H-bridge inverter topology seems to be a promising solution. Both five-phase and six-phase present similar results. However, six-phase drive could be more interesting, as it could be brought close to standard three-phase solutions and adapted to dual-lane supply.

Consulter en ligne

Suggestions

Du même auteur

An approach to compare multiphase drives for automotive safety applications

Archive ouverte: Communication dans un congrès

Ribiere, Antonin | 2022-06

International audience. Automotive safety applications will be soon a standard based on market evolution trends. Actuators performing safety operations, such as steering or braking, need to be more reliable with a l...

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2015-06

International audience. This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in...

Signal-based Technique for Fault Detection and Isolation of Inverter Faults...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2012-12-17

International audience. A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitabl...

Du même sujet

Electric Vehicles Driven by 5-phase Open-End Winding Machines Fed by Batter...

Archive ouverte: Communication dans un congrès

Vu, Duc Tan | 2019-10-15

International audience. This paper presents the modeling and control of an Electric Vehicle (EV) driven by a 5-phase Permanent Magnet Synchronous Machine (PMSM). The machine in an open-end winding configuration is s...

Fault-Tolerant Control for Non-sinusoidal Seven-phase PMSMs with Similar Co...

Archive ouverte: Communication dans un congrès

Vu, Duc Tan | 2022-07-27

International audience. This paper proposes a strategy using new transformation matrices to calculate new current references when a non-sinusoidal seven-phase permanent magnet synchronous machine (PMSM) has an open-...

Fault-tolerant Control for Non-sinusoidal Multiphase Drives with Minimum To...

Archive ouverte: Article de revue

Vu, Duc Tan | 2021-12-09

International audience. For non-sinusoidal electromotive force (NS-EMF) multiphase machines, this paper proposes a new strategy and control scheme to guarantee smooth torque under an open-phase fault. Notably, the c...

Fault-tolerant Control for 7-phase Non-sinusoidal Permanent Magnet Machines...

Archive ouverte: Communication dans un congrès

Yanagihara, Keitaro | 2019-10-10

International audience. This paper presents new fault-tolerant control strategies for field-oriented control of 7-phase non-sinusoidal permanent magnet (PM) machines supplied by voltage source inverters (VSI). Singl...

Generation of On-line Optimal Current References for Multi-phase Permanent ...

Archive ouverte: Communication dans un congrès

Kestelyn, Xavier | 2009-05

Acces éditeur : URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5075280&isnumber=5075166. This paper deals with the generation of optimal current references for Multi-phase Permanent Magnet Machines wit...

Different Virtual Stator Winding Configurations of Open-End Winding Five-Ph...

Archive ouverte: Communication dans un congrès

Nguyen, N.K | 2013-09-03

International audience. This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pe...

Chargement des enrichissements...