Quantitative assessment of primary mitral regurgitation using left ventricular volumes obtained with new automated three-dimensional transthoracic echocardiographic software: A comparison with 3-Tesla cardiac magnetic resonance

Archive ouverte : Article de revue

Levy, Franck | Marechaux, Sylvestre | Iacuzio, Laura | Schouver, Elie Dan | Castel, Anne Laure | Toledano, Manuel | Rusek, Stephane | Dor, Vincent | Tribouilloy, Christophe | Dreyfus, Gilles

Edité par HAL CCSD ; Elsevier/French Society of Cardiology

International audience. Background. - Quantitative assessment of primary mitral regurgitation (MR) using left ventricular (LV) volumes obtained with three-dimensional transthoracic echocardiography (3D TTE) recently showed encouraging results. Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time consuming. Aims. - To investigate the accuracy and reproducibility of new automated fast 3D TTE software (HeartModel(A.I.); Philips Healthcare, Andover, MA, USA) for the quantification of LV volumes and MR severity in patients with isolated degenerative primary MR; and to compare regurgitant volume (RV) obtained with 3D TTE with a cardiac magnetic resonance (CMR) reference. Methods. - Fifty-three patients (37 men; mean age 64 +/- 12 years) with at least mild primary isolated MR, and having comprehensive 3D TTE and CMR studies within 24 h, were eligible for inclusion. MR RV was calculated using the proximal isovelocity surface area (PISA) method and the volumetric method (total LV stroke volume minus aortic stroke volume) with either CMR or 3D TTE. Results. - Inter- and intraobserver reproducibility of 3D TTE was excellent (coefficient of variation <= 10%) for LV volumes. MR RV was similar using CMR and 3D TTE (57 +/- 23 mL vs 56 28 mL; P=0.22), but was significantly higher using the PISA method (69 +/- 30 mL; P<0.05 compared with CMR and 3D TTE). The PISA method consistently overestimated MR RV compared with CMR (bias 12 +/- 21 mL), while no significant bias was found between 3D TTE and CMR (bias 2 +/- 14 mL). Concordance between echocardiography and CMR was higher using 3D TTE MR grading (intraclass correlation coefficient [ICC] = 0.89) than with PISA MR grading (ICC = 0.78). Complete agreement with CMR grading was more frequent with 3D TTE than with the PISA method (76% vs 63%). Conclusion. - 3D TTE RV assessment using the new generation of automated software correlates well with CMR in patients with isolated degenerative primary MR. (C) 2018 Elsevier Masson SAS. All rights reserved.

Consulter en ligne

Suggestions

Du même auteur

Performance of new automated transthoracic three-dimensional echocardiograp...

Archive ouverte: Article de revue

Levy, Franck | 2017

International audience. Background. - Three-dimensional (3D) transthoracic echocardiography (TTE) is superior to two-dimensional Simpson's method for assessment of left ventricular (LV) volumes and LV ejection fract...

Assessment of left ventricular size and function by 3-dimensional transthor...

Archive ouverte: Article de revue

Castel, Anne Laure | 2018

International audience. Background: Whether echocardiography platform and analysis software impact left ventricular (LV) volumes, ejection fraction (EF), and stroke volume (SV) by transthoracic tridimensional echoca...

Comparison of Mitral Regurgitant Volume Assessment between Proximal Flow Co...

Archive ouverte: Article de revue

Altes, Alexandre | 2022

International audience. BACKGROUND: Discrepancies have been observed between transthoracic echocardiography (TTE) and cardiac magnetic resonance imaging (CMR) severity grading in primary mitral regurgitation (MR). O...

Du même sujet

Proteolytic activity of Lactobacillus strains isolated from Mongolian tradi...

Archive ouverte: Article de revue

Raveschot, Cyril | 2020-01-30

Le Réseau Mixte Technologique Sols et Territoires : développer la connaissa...

Archive ouverte: Article de revue

Guellier, Camille | 2014

absent

Soil bioindicators: how soil properties influence their responses and to se...

Archive ouverte: Communication dans un congrès

Pauget, Benjamin | 2015-05-03

International audience

Les incitations financières à la réalisation d’objectifs comportementaux li...

Archive ouverte: Article de revue

Crainich, David | 2022-02

International audience. Les programmes octroyant des récompenses pécuniaires aux individus qui parviennent à atteindre un objectif lié à la santé (arrêter de fumer, perdre du poids, etc.) ont pour but de favoriser l...

Transcriptome assembly and abiotic related gene expression analysis of date...

Archive ouverte: Article de revue

Rekik, Imen | 2019-11-30

Characterization of free exopolysaccharides secreted by Mycoplasma myco...

Archive ouverte: Article de revue

Bertin, Clothilde | 2013

International audience. Contagious bovine pleuropneumonia is a severe respiratory disease of cattle that is caused by a bacterium of the Mycoplasma genus, namely Mycoplasma mycoides subsp. mycoides (Mmm). In the abs...

Chargement des enrichissements...